Mixing by aspiration—mixing of sample by aspiration in lieu of shaking assures homogeneity in the sample and maintains mobile viability

The CytKick Max Autosample incorporates a boost method that allows more quickly sample processing, and passive cooling for some plates/racks. A CytKick Max Accessory Package is included which contains four accessory plates: two cooling plates and two tube adaptors, in addition to a Max dongle vital. A computer just isn't bundled Using the autosampler due to the fact 1 is provided with the cytometer.

To forestall probe crashes, which can require pricey probe alternative, the CytKick Max Autosampler mechanically performs a probe self-calibration to help make sure steady positioning with the probe in just every nicely. The self-calibration verifies appropriate operate on the probe, lessens variability in probe positioning eventually to circumvent failures during plate operates, and allows improve trustworthiness around the lifetime of the process.

Compared with other plate loaders that blend samples by shaking, which may not make certain homogeneity from the sample, the CytKick Max Autosampler mixes samples by aspiration and stirring, enabling uniform mixing whilst preserving sample viability and resulting in consistent details with CVs a lot less than ten% through the plate. The CytKick Max Autosampler also has a mild mix mode for fragile mobile strains.

The autosampler’s indicator lights and warning systems are actually intended in order that a consumer who has walked clear of the process can easily begin to see the technique status at all times.

To keep up method adaptability, the guide sample probe is often available even when the loader is current, and switching in between tubes and plates is detected by using application and doesn't have to have further person intervention.

The CytKick Max Autosampler was intended to minimize technique down time. Automatic sampling units are often affected by clogging or probe crashes. The Clever Probe, using a two hundred-micron diameter that's much larger than most probes accessible from the industry, minimizes cases of clogging.

The intuitive software permits speedy Studying and info Investigation. For instance, a heat map look at lets quick screening and affirmation of samples though the instrument is acquiring info.

Effortless changeover—no disassembly, no more QC, no reboot demanded for conversion between plates and tubes

The CytKick Max Autosampler has two options for processing samples within a substantial-throughput natural environment: superior-throughput manner and Strengthen manner.

Self-calibration of your probe also allows the autosampler to be effortlessly moved, so it can be shared in between numerous devices.

The instrument style and computer software have been produced with client ease-of-use in mind. The CytKick Max Autosampler has fluidic bottles with sensors that advise the person if the fluids ought to be replaced.

Autocleaning of autosampler is done throughout the instrument shutdown process therefore no supplemental consumer measures are needed to take care of process.

Putting together an experiment Together with the Attune NxT cytometric computer software is pe autosampler simple. Employing a plate layout view, people can generate compensation wells, determine instrument settings, and identify samples.